Appendix A. CRBasic Programming Instructions
488
SW12
Setsaswitched12Vdcterminalhighorlow.
Syntax
SW12(State)
A.5.6 Pulse and Frequency
Read More! See Pulse (p. 318).
Note Pull-up resistors are required when using digital I/O (control) ports for
pulse input (see Pulse Input on Digital I/O Channels C1 - C8 (p. 321) ).
PeriodAvg
Measurestheperiodofasignalonanysingleendedvoltageinputchannel.
Syntax
PeriodAvg(Dest, Reps, Range, SEChan, Threshold, PAOption,
Cycles, Timeout, Mult, Offset)
PulseCount
Measuresnumberorfrequencyofvoltagespulsesonapulsechannel.
Syntax
PulseCount(Dest, Reps, PChan, PConfig, POption, Mult, Offset)
VibratingWire
TheVibratingWireinstructionisusedtomeasureavibratingwiresensorwitha
sweptfrequency(fromlowtohigh).
Syntax
VibratingWire(Dest, Reps, Range, SEChan, Vx/ExChan,
StartFreq, EndFreq, TSweep, Steps, DelMeas, NumCycles,
DelReps, Multiplier, Offset)
A.5.7 Digital I/O
CheckPort
Returnsthestatusofacontrolport.
Syntax
X = CheckPort(Port)
PortGet
Readsthestatusofacontrolport.
Syntax
PortGet(Dest, Port)
PortsConfig
Configurescontrolportsasinputoroutput.
Syntax
PortsConfig(Mask, Function)
ReadIO
ReadsthestatusofselectedcontrolI/Oports.
Syntax
ReadIO(Dest, Mask)