INSTRUCTION MANUAL
CS500 Temperature and
Relative Humidity Probe
Revision: 7/04
Copyright (c) 1995-2004
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - INSTRUCTION MANUAL

INSTRUCTION MANUALCS500 Temperature andRelative Humidity ProbeRevision: 7/04Copyright (c) 1995-2004Campbell Scientific, Inc.

Página 2 - Warranty and Assistance

CS500 Temperature and Relative Humidity Probe6TABLE 1. Datalogger ConnectionsDescription Color CR23X/CR1000 CR10(X), CR510 21X, CR7Temperature Black

Página 3 - CS500 Table of Contents

CS500 Temperature and Relative Humidity Probe7TABLE 4. Wiring for CR1000 and CR10X ExamplesDescription Color CR1000 CR10(X)Temperature Black SE 1 SE

Página 4

CS500 Temperature and Relative Humidity Probe8;Measure the CS500 relative humidity.;02: Volt (SE) (P1)1: 1 Reps2: 5 2500 mV Slow Range ;CR500 (2500 m

Página 5 - Humidity Probe

CS500 Temperature and Relative Humidity Probe9This voltage drop will raise the apparent temperature and relative humiditybecause the difference betwee

Página 6 - 3. Installation

CS500 Temperature and Relative Humidity Probe10Example 1. Sample CR10(X) Program that Computes Vapor Pressureand Saturation Vapor Pressure;Measure th

Página 7

CS500 Temperature and Relative Humidity Probe11;Compute the vapor pressure in kPa.;Relative humidity must be a fraction.;07: Z=X*Y (P36)1: 3 X Loc [

Página 8

CS500 Temperature and Relative Humidity Probe12This is a blank page.

Página 9 - Clear Shield

This is a blank page.

Página 10 - 5. Example Programs

Campbell Scientific CompaniesCampbell Scientific, Inc. (CSI)815 West 1800 NorthLogan, Utah 84321UNITED [email protected]

Página 11 - 5.2 Example for CR10X

Warranty and AssistanceThe CS500 TEMPERATURE AND RELATIVE HUMIDITY PROBE iswarranted by CAMPBELL SCIENTIFIC, INC. to be free from defects inmaterials

Página 12 - 6. Long Lead Lengths

iCS500 Table of ContentsPDF viewers note: These page numbers refer to the printed version of this document. Usethe Adobe Acrobat® bookmarks tab for

Página 14

1CS500 Temperature and RelativeHumidity Probe1. GeneralThe CS500 Temperature and Relative Humidity probe contains a PlatinumResistance Temperature de

Página 15 - 9. References

CS500 Temperature and Relative Humidity Probe2Temperature Accuracy:00.40.81.21.6-0.4-0.8-1.2-1.6-20-40 0Temperature( C)o( C)Erroro20 40 60 2.2

Página 16 - This is a blank page

CS500 Temperature and Relative Humidity Probe3The CS500 is held in place, within the 41003 or UT12VA Radiation Shield, viaan adapter, Model 41381. Th

Página 17

CS500 Temperature and Relative Humidity Probe4FIGURE 2. CS500 and 41303 Radiation ShieldFIGURE 3. CS500 and 41003 Radiation Shieldon a CM6/CM10 Trip

Página 18 - Campbell Scientific Companies

CS500 Temperature and Relative Humidity Probe5FIGURE 4. Radiation Shield, CS500, and 41381 AdapterFIGURE 5. CS500 Wiring41003 10-Plate Radiation Shi

Comentários a estes Manuais

Sem comentários