Campbell-scientific EnviroSCAN Sentek Water Content Profile Probe Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Campbell-scientific EnviroSCAN Sentek Water Content Profile Probe. Campbell Scientific EnviroSCAN Sentek Water Content Profile Probe User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Content Profile Probes

EnviroSMART™ Soil WaterContent Profile ProbesRevision: 3/09Copyright © 2002-2009Campbell Scientific, Inc.EnviroSMART™, EasyAG®, and IrriMAX® are trad

Página 2 - Warranty and Assistance

EnviroSMARTTM Soil Water Content Profile Probes 8.2 Cable Installation Securely tighten the gland nut through which the cable passes into the probe c

Página 3 - Table of Contents

EnviroSMARTTM Soil Water Content Profile Probes ‘Program Control Variables Dim X ‘Definition of DataTables DataTable (ES1_SF,1,-1) Sample

Página 4 - Figures

EnviroSMARTTM Soil Water Content Profile Probes Else ‘...OR... If ES1_SF(X) < -999 Then ‘If a WC sensor fails (indicated by

Página 5

EnviroSMARTTM Soil Water Content Profile Probes ;Wiring: EnviroSMART / EasyAG 12 Volts (Pin 1) -------- CR10X 12 V ; EnviroSMART / EasyAG G

Página 6 - 5. Resolution and Accuracy

EnviroSMARTTM Soil Water Content Profile Probes 7: If (X<=>F) (P89) 1: 1 X Loc [ ES1_SF_1 ] 2: 2 <> 3: 0 F 4: 3

Página 7

EnviroSMARTTM Soil Water Content Profile Probes 17: If (X<=>F) (P89) ;If 1st sensor reading is < -9999 i.e. = -99999 1: 1 X Loc

Página 8 - 6. Specifications

EnviroSMARTTM Soil Water Content Profile Probes 28: Z=X^Y (P47) 1: 9 -- X Loc [ ES1_WC_1 ] 2: 34 Y Loc [ RecipB ] 3: 9 --

Página 9 - 8. Probe Wiring

EnviroSMARTTM Soil Water Content Profile Probes 40: Sample (P70) 1: 1 Reps 2: 26 Loc [ Irrig_mm ] ;Output Water Content Data to Storage 4

Página 10 - 9. Datalogger Programming

EnviroSMARTTM Soil Water Content Profile Probes 14 28 _________ 0 0 0 29 C 1 1 0 30 A 1 1 0 31 _________ 0 0 0 32 B 1 1 0 33 _

Página 11

Appendix A. Probe Assembly FIGURE A-1. Finished EnviroSMARTTM Assembly Figure A-1 shows a finished three-sensor probe. Your probe may require more

Página 12

Warranty and Assistance The EnviroSMART™ SOIL WATER CONTENT PROFILE PROBES are warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in mater

Página 13

Appendix A. Probe Assembly “Loosely” attach the handle to the rod with two of the large screws that came with the assembly as shown in Figure A-3. F

Página 14

Appendix A. Probe Assembly FIGURE A-7. Sensor Orientation FIGURE A-8. Sensor Ribbon Cable Determine the number and locations of sensors that are

Página 15

Appendix A. Probe Assembly FIGURE A-10. Aligning Sensor Tab with Probe Slot FIGURE A-11. Plugging in Ribbon Cable Header Advance the sensor to it

Página 16

Appendix A. Probe Assembly FIGURE A-13. Location of Addressing Jumpers FIGURE A-14. Location of Jumper 1 FIGURE A-15. Location of Jumper 2 A-5

Página 17

Appendix A. Probe Assembly FIGURE A-16. Location of Jumpers 1..16 After positioning and securing each sensor in its proper location, install the ju

Página 18 - 11. Acknowledgements

Appendix B. Normalization and Function Test Normalization is the setting of the range over which the electronics is effective. This range is bounded

Página 19 - Appendix A. Probe Assembly

Appendix B. Normalization and Function Test Start the IPConfig Utility (Intelligent Probe Utility Software, P/N SEN06025) on the PC by clicking on th

Página 20

Appendix B. Normalization and Function Test 1. Click on “Auto-detect Sensors” in the lower left corner. Wait until all sensors are auto-detected.

Página 21

Appendix B. Normalization and Function Test B.1.2 TriSCAN Normalization When normalizing TriSCAN sensors for water content, follow the procedure in

Página 22

Appendix B. Normalization and Function Test B.2 Configuration Testing FIGURE B-6. IPConfig Configuration Test Window Test the configuration by goi

Página 23

EnviroSMARTTM Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks

Página 24

Appendix B. Normalization and Function Test B-6 This is a blank page.

Página 25 - Function Test

Appendix C. Access Tube Installation The information below is a summary. Further information is provided in the Sentek Diviner2000® Installation Gui

Página 26 - B.1.1 Water Content Only

Appendix C. Access Tube Installation C.1 Standard Access Tube Installation C.1.1 Installation Tools Toolkit items Installation Toolkit No. 1 Items

Página 27

Appendix C. Access Tube Installation C.1.2 Installing the Access Tube Figure C-1. Incorrect Installation To install the access tube, follow these

Página 28 - B.1.2 TriSCAN Normalization

Appendix C. Access Tube Installation 11. Use a sledgehammer to tap the dolly until the access tube is embedded approximately 5-10 cm into the soil.

Página 29 - B.2 Configuration Testing

Appendix C. Access Tube Installation 5. Select Access Tube Cleaning Tool no. 3 — rag tool. Insert a clean cotton cloth into the eyelet and saturat

Página 30 - This is a blank page

Appendix C. Access Tube Installation 5. Wipe off excess silicon from the inside of the access tube. 6. Screw the cap back onto the top cap housing.

Página 31

Appendix C. Access Tube Installation 16. Winch the access tube carefully upward and out of the ground. 17. Remove the access tube from the extract

Página 32 - C.1.1 Installation Tools

Appendix C. Access Tube Installation C-8 This is a blank page.

Página 33

Appendix D. Site Selection Site selection is a critical process for all soil water sensors. A properly selected site will reflect changes in soil mo

Página 34

EnviroSMARTTM Table of Contents ii B. Normalization and Function Test...B-1 B.1 Normalization...

Página 35

This is a blank page.

Página 36 - C.2 Access Tube Removal

Appendix E. SDI-12 Commands The SDI-12 EnviroSMART probe interface communicates with Campbell Scientific dataloggers by way of SDI-12 protocol. A co

Página 37

This is a blank page.

Página 39 - Appendix D. Site Selection

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 40

EnviroSMARTTM Soil Water Content Profile Probes 1. General EnviroSMARTTM probes measure a profile of volumetric soil water content. EnviroSMART prob

Página 41 - Appendix E. SDI-12 Commands

EnviroSMARTTM Soil Water Content Profile Probes 4.1 Water Content Sensor output is a dimensionless frequency (raw count) that is converted via a norm

Página 42

EnviroSMARTTM Soil Water Content Profile Probes VIC can be related directly to a site-specific soil EC through the use of Sentek’s Benchmarking Proced

Página 43

EnviroSMARTTM Soil Water Content Profile Probes 6. Specifications Feature EnviroSMARTTM SDI-12 Maximum cable length to logger or third party device 6

Página 44

EnviroSMARTTM Soil Water Content Profile Probes 7. Installation Several configurations are possible when using the EnviroSMARTTM / EasyAG® Probes wit