Appendix B. Example Programs
B.1.2 Example Program for CR1000 Datalogger
'CR1000 Series Datalogger
'Declare the variable for the water level measurement
Public CS451(2)
'Rename the variable names
Alias CS451(1)=Level
Alias CS451(2)=Temp_C
'Define a data table for 60 minute maximum and minimums
DataTable(Hourly,True,-1)
DataInterval(0,60,Min,10)
Maximum(1,Level,FP2,0,0)
Minimum(1,Level,FP2,0,0)
Maximum(1,Temp_C,FP2,0,0)
Minimum(1,Temp_C,FP2,0,0)
EndTable
'Read sensor every 60 seconds
BeginProg
Scan(60,sec,1,0)
'Code for SDI-12 measurements:
SDI12Recorder(CS451,1,”0”,”M!”,1,0)
'Call the data table:
CallTable(Hourly)
NextScan
EndProg