CS420-L and CS425-L Pressure Transducers
7. Edlog Program Examples
7.1 CR10(X), CR510, and CR500 Examples
7.1.1 Instruction 6 (4-Wire Full Bridge Measurement)
7.1.1.1 Wiring
Datalogger CS420-L/CS425-L
Excitation E1 Red (Supply +)
Input H1 Yellow (Output +)
Input L1 Blue (Output -)
An. Ground AG White (Supply -)
G Clear (Shield)
The orange and black wires are not used and the ends of these wires should be
taped to prevent shorting.
7.1.1.2 Edlog Program
; Measure one 4-wire DRUCK Sensor.
* Table 1 Program
01: 5 Execution Interval (seconds)
1: Full Bridge (P6)
1: 1 Reps
2: 3 25 mV slow range
3: 1 DIFF channel
4: 1 Excite all reps w/Exchan 1
5: 2500 mV excitation
6: 1 Loc [DEPTH_FT]
7: 2.3529 Mult
8: -0.49 Offset
; Every 60 minutes output the array ID, time,
; and average water depth in feet
2: If Time Is (P92)
1: 0 Minutes (seconds --) into
2: 60 Interval (same units as above)
3: 10 Set output flag high (Flag 0)
3: Real Time (P77)
1: 110 Day, Hour/Minute (midnight = 0000)
4: Average (P71)
1: 1 Reps
2: 1 Loc [DEPTH_FT]