Appendix C. MD485 to RF401 Network
RF401 Configuration
The RF401s may be left in their default settings. However, if there is a
neighboring RF401 network, you should change the Hopping Sequence of
base and remote RF401s to a new setting to avoid interference.
When using MD9 Emulation, after disconnecting from a
datalogger, you must wait for a 40-second timeout before being
able to connect again.
NOTE
4. PAKBUS NETWORKING
PC-MD485---MD485--null modem---RF401---RF401-DL
LoggerNet Setup
a. Setup:
ComPort_1
PakBus Port
CR1000
b. ComPort_1 – default settings
c. PakBus Port – defaults
d. Dataloggers – corresponding PakBus address, other setting default,
schedule collections as desired
MD485 Configuration
a. Base MD485
1) Active Ports – “RS-232 and RS-485”
2) Communication Mode – “PakBus Networking”
3) RS-232 Port Configuration – Desired baud rate
4) RS-485 Port Configuration – Desired baud rate
b. Remote MD485s
1) Active Ports – “RS-232 and RS-485”
2) Communication Mode – “PakBus Networking”
3) RS-232 Port Configuration – Desired baud rate
4) RS-485 Port Configuration – Desired baud rate
RF401 Configuration
The RF401s may be left in their default settings. However, if there is a
neighboring RF401 network, you should change the Hopping Sequence of
base and remote RF401s to a new setting to avoid interference.
C-6