Campbell-scientific SR50-L CSC Ultrasonic Distance Sensor Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 38
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
SR50 Sonic Ranging Sensor
13
The following instructions set the sensor enable line high long enough for the
SR50 to detect it, then set it low.
1: Set Port (P20)
1: 1 Set High
2: 1 Port Number
2: Excitation with Delay (P22)
1: 1 Ex Chan
2: 1 Delay w/Ex (units = 0.01 sec)
3: 0000 Delay After Ex (units = 0.01 sec)
4: 0.0 mV Excitation
3: Set Port (P20)
1: 0 Set Low
2: 1 Port Number
The P3 instruction counts the pulse train being transmitted from the SR50.
Distance-to-surface will automatically be reset to 0.00 after the distance is
calculated and stored for later processing and output.
4: Pulse (P3)
1: 1 Reps
2: 1 Pulse Input Chan
3: 00 Config Option
4: 21 Loc [ Dis2Surf ]
5: -.0025 Mult
6: 0.0 Offset
Measure air temperature and convert to degrees Kelvin. This example assumes
air temperature is being measured with Campbell Scientific’s Model 107
probe.
5: Temp 107 Probe (P11)
1: 1 Reps
2: 1 In Chan
3: 1 Excite all reps w/Exchan 1
4: 22 Loc [ T_Kelvin ]
5: 1 Mult
6: 273.15 Offset
Compute the air temperature compensation factor and correct the distance-to-
surface for air temperature (see formula 1).
6: Z=F (P30)
1: 273.15 F
2: 23 Z Loc [ 273_15 ]
7: Z=X/Y (P38)
1: 22 X Loc [ T_Kelvin ]
2: 23 Y Loc [ 273_15 ]
3: 24 Z Loc [ ATempComp ]
Vista de página 18