CS440 Liquid Level Senso
r
Revision: 9/06
Copyright © 2006
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 13 14

Resumo do Conteúdo

Página 1 - CS440 Liquid Level Senso

CS440 Liquid Level SensorRevision: 9/06Copyright © 2006Campbell Scientific, Inc.

Página 2 - Warranty and Assistance

CS440 Liquid Level Sensor 6 After this command is executed, the input location within the logger called “Level” holds the measured pressure, reported

Página 3 - CS440 Table of Contents

CS440 Liquid Level Sensor 7 • Check battery condition (physical and *6 mode of the datalogger) • Check all sensor readings (*6 mode of the datalogge

Página 4

CS440 Liquid Level Sensor 8 Suggestion: A kinked or plugged vent tube will not effectively vent a gauge pressure (vented) type of device. Normal chan

Página 6 - 3. Installation

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Página 7 - 4. Wiring

Warranty and Assistance The CS440 LIQUID LEVEL SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship u

Página 8 - 5. Programming Example

i CS440 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab f

Página 9 - 5.3 Using Edlog

This is a blank page.

Página 10 - 6. Maintenance

1 CS440 Liquid Level Sensor 1. Introduction This manual describes using the CS440, ACData Solutions’ SPXD-500 submersible pressure transducer with Ca

Página 11 - 7. Troubleshooting Hints

CS440 Liquid Level Sensor 2 Notes: 1. Includes Linearity, Repeatability and Pressure Hysteresis at 25 °C. 2. 0 – 50 °C, Referenced to 25°C. Specificat

Página 12

CS440 Liquid Level Sensor 3 Although the cable jacket is made from a thick, tough polyurethane formation, care should be taken to avoid cable damage.

Página 13 - This is a blank page

CS440 Liquid Level Sensor 4 IMPORTANT: Current measurements such as 4-20 mA signals vary widely in how they can be powered and connected to a datalogg

Página 14

CS440 Liquid Level Sensor 5 Multiplier and Offset The Multiplier and Offset can be changed to scale the result or perform unit conversions. The VoltS