WindSonic Two-Dimensional
Sonic Anemometer
Revision: 8/13
Copyright © 2004-2013
Campbell Scientific, Inc.
Vista de página 0
1 2 3 4 5 6 ... 45 46

Resumo do Conteúdo

Página 1 - Sonic Anemometer

WindSonic Two-Dimensional Sonic AnemometerRevision: 8/13 Copyright © 2004-2013Campbell Scientific, Inc.

Página 2

WindSonic Two-Dimensional Sonic Anemometer • The black outer jacket of the cable is Santoprene® rubber. This compound was chosen for its resistance

Página 3 - Warranty

WindSonic Two-Dimensional Sonic Anemometer 5. Mount the crossarm to the tripod or tower. 6. Orient the WindSonic so that the colored North marker ar

Página 4 - Assistance

WindSonic Two-Dimensional Sonic Anemometer 4.3 Use Short Cut Program Generator for Windows (SCWin) to Program Datalogger and Generate Wiring Diagram

Página 5 - Table of Contents

WindSonic Two-Dimensional Sonic Anemometer 3. Select WindSonic4 (SDI-12) Two Dimensional Ultrasonic Wind Sensor and select the right arrow (in center

Página 6

WindSonic Two-Dimensional Sonic Anemometer 5. Select the outputs and then select finish. 6. Wire according to the wiring diagram generated by SCWi

Página 7

WindSonic Two-Dimensional Sonic Anemometer 5. Overview The WindSonic is an ultrasonic anemometer for measuring wind direction and wind speed. It use

Página 8

WindSonic Two-Dimensional Sonic Anemometer 6. Specifications Features: • Low maintenance—no moving parts significantly reduces maintenance cost and

Página 9 - Anemometer

WindSonic Two-Dimensional Sonic Anemometer 6.4 Campbell Scientific Factory Default Settings for the WindSonic1 The default settings for the WindSonic

Página 10 - 4. Quickstart

WindSonic Two-Dimensional Sonic Anemometer White DotFIGURE 6-1. White dot indicating that the WindSonic1 has the newer settings 7. Operation 7.1 S

Página 11

WindSonic Two-Dimensional Sonic Anemometer 7.2 Wiring 7.2.1 Serial Wiring (COMn) CRBasic dataloggers (CR800 series, CR1000, and CR3000) support seri

Página 13

WindSonic Two-Dimensional Sonic Anemometer 7.2.3 SDI-12 Wiring The WindSonic4 interfaces to a Campbell Scientific datalogger using SDI-12. SDI-12 is

Página 14

WindSonic Two-Dimensional Sonic Anemometer TABLE 7-5. CRBasic Datalogger OperatingSystems that Support RS-232 Communications and SerialInRecord() Da

Página 15 - 5. Overview

WindSonic Two-Dimensional Sonic Anemometer FieldNames ("diag_10_TOT") Totalize (1,n,IEEE4,nmbr_bytes_rtrnd<>0) FieldNames ("

Página 16 - 6. Specifications

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,n,IEEE4,diag<>2) FieldNames ("diag_2_TOT") Totalize (1,n,IEEE4,diag<&g

Página 17 - WindSonic1

WindSonic Two-Dimensional Sonic Anemometer The WindSonic4 returns three data points; the datalogger program must allocate three consecutive input loca

Página 18 - 7. Operation

WindSonic Two-Dimensional Sonic Anemometer 7.4.1 Example CR10X (Edlog) Datalogger Program for Measuring a WindSonic4 TABLE 7-10. Wiring for CR10(X)

Página 19 - 7.2 Wiring

WindSonic Two-Dimensional Sonic Anemometer 8: If (X<=>F) (P89) 1: 3 X Loc [ ws_diag ] 2: 2 <> 3: 0 F 4: 19 Set Inte

Página 20 - 7.2.3 SDI-12 Wiring

WindSonic Two-Dimensional Sonic Anemometer 17: If (X<=>F) (P89) 1: 3 X Loc [ ws_diag ] 2: 1 = 3: 8 F 4: 29 Set Intermed.

Página 21

WindSonic Two-Dimensional Sonic Anemometer *Table 3 Subroutines End Program -Input Locations- 1 wnd_dir 2 wnd_spd 3 ws_diag 4 samples 7.4.2 Exampl

Página 22

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,one,diag<>NaN) FieldNames ("no_data_TOT") EndTable BeginProg one = 1 Scan

Página 23

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Página 24

WindSonic Two-Dimensional Sonic Anemometer Totalize (1,one,IEEE4,diag<>10) FieldNames ("diag_10_TOT") Totalize (1,one,IEEE4,diag<

Página 25 - WindSonic4

WindSonic Two-Dimensional Sonic Anemometer • To activate the SDI-12 Transparent Mode, on Control Port p, enter pX and press the <enter> key. T

Página 26

WindSonic Two-Dimensional Sonic Anemometer 7.5.2 Table-Based Edlog Dataloggers • Connect a single WindSonic4 to the datalogger Control Port p as des

Página 27

WindSonic Two-Dimensional Sonic Anemometer FIGURE 7-2. SDI-12 Transparent Mode on an Edlog table-based datalogger using control port 8 and changing

Página 28

WindSonic Two-Dimensional Sonic Anemometer press the <enter> key. The WindSonic4 will respond with the current SDI-12 address. • To change the

Página 29

WindSonic Two-Dimensional Sonic Anemometer (refer to the Assistance section at the beginning of this manual for the process of returning a product to

Página 30 - Datalogger

WindSonic Two-Dimensional Sonic Anemometer 28 10. Siting References The following references give detailed information on siting wind direction and w

Página 31

Appendix A. WindSonic Orientation A.1 Determining True North and Sensor Orientation The orientation of the WindSonic “North Arrow Markers” is found

Página 32

Appendix A. WindSonic Orientation Declination angles east of True North are considered negative, and are subtracted from 360 degrees to get True Nort

Página 33

Appendix A. WindSonic Orientation A.2 Online Magnetic Declination Calculator The magnetic declination calculator web calculator published by NOAA’s

Página 34 - 8. Maintenance

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Página 35 - 9. Diagnostic Codes

Appendix A. WindSonic Orientation A-4

Página 36 - 10. Siting References

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings In February 2013, the settings of the WindSonic1 sensor were

Página 37

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings New CR1000 Program (Section 7.3.1) (Public variables change.

Página 38

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings New CR1000 SDM-SIO1 Program (from Section 7.3.2) (Public varia

Página 39

Appendix B. Updating an Older Program for Measuring a WindSonic1 With the New Settings B-4

Página 41 - With the New Settings

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 42

Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to spec

Página 43

Table of Contents 7.5 Changing the SDI-12 Address Using LoggerNet and a Datalogger .. 22 7.5.1 Array-Based Edlog Dataloggers...

Página 44

Table of Contents 7-8. WindSonic Data Format Option...15 7-9. Datalogger Operating Systems tha

Página 45

Table of Contents iv

Página 46

WindSonic Two-Dimensional Sonic Anemometer 1. Introduction The WindSonic1 and WindSonic4 are two-dimensional ultrasonic anemometers for measuring wi