4.4 Wind Speed and Direction
The wind set attaches to the connector labeled WS/WD; this connector is color
coded red. The wind set is internally wired from the RAWS connector panel to
the CR1000 datalogger.
TABLE 4-4. WS/WD Connector (color coded red)
Connector Pin Description CR1000 Terminal
A Sensor Ground
B Wind Direction Excitation VX2
C Wind Direction Signal 2H
D Power Ground G
E +12 V power 12V
F Wind Speed Signal P1
4.4.1 SDI-12 Sensor
An SDI-12 sensor can be attached to the connector labeled SDI-12; this
connector is color coded yellow. The SDI-12 sensor is internally wired from
the RAWS connector panel to the CR1000 datalogger.
TABLE 4-5. SDI-12 Connector (color coded yellow)
Connector Pin Description Datalogger Connection
A SDI-12 Signal C7
B 12 V 12V
C Power Ground G
4.5 Fuel Moisture and Fuel Temperature
The Campbell Scientific CS506 and CS205 sensors are combined into one
connector (pn CS516-LQ). This sensor is internally wired from the RAWS
connector panel to the CR1000 datalogger. This sensor attaches to the
connector labeled FM/FT, which is color coded brown.