Campbell-scientific ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Campbell-scientific ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures. Campbell Scientific ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Revision: 8/12

Campbell Scientific EnclosuresRevision: 8/12 Copyright © 2006-2012Campbell Scientific, Inc.

Página 2

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 3. Mounting Equipment Inside the Enclosure 3.1 Enclosures

Página 3 - Warranty

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 4. If desired, insert the 25745 PVC coupling to reduce the

Página 4 - Assistance

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 3-2. Securing cables to the cable tie tabs 6

Página 5 - Enclosures Table of Contents

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 3-3. An ENC12/14 with one 1.5" conduit houses

Página 6 - Figures

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 3. Route each sensor and peripheral lead through a unique c

Página 7 - PWENC14/16, and PWENC16/18

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 3-5. This ENC16/18 enclosure with the “-ES” option

Página 8 - 1.1 Specifications

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 4-1. An enclosure with the “-MM” mounting option at

Página 9 - 2. Enclosure Supply Kit

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 4-3. An enclosure attached to a tripod mast 4.2 UT

Página 10

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 same three-piece brackets as the “-MM” option, except the pi

Página 11

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 The default configuration is for attaching to a UT10 tower (

Página 13

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 4.4 Tripod Leg Base The “-LM” mount option is intended for

Página 14

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 Flange FIGURE 4-7. The 19124 bracket attached to a CM110 t

Página 15 - 4.1 Tripod Mast

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 FIGURE 4-9. The u-bolt bracket FIGURE 4-10. An enc

Página 16

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 4.4.1 Mounting More Than One Enclosure on a Tripod Leg (CM1

Página 17 - 4.3 UT20 or UT30 Tower

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 EnclosureBracketLockNutWasherBolt FIGURE 4-12. Attaching th

Página 18

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 5. Insert the tab on the end of the Screw Threads (FIGURE 4

Página 19

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 5. When to Replace Desiccant The humidity indicator card or

Página 20 - 4.4 Tripod Leg Base

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 3. Use a fine grain sandpaper to gently sand the enclosure

Página 21

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 22

Página 22

Appendix A. Door Switch A.1 Installation Procedure 1. The Door Open Indicator Kit contains several small brackets that are used to mount the senso

Página 23 - 4.5 Pole Mount

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Página 24

Appendix A. Door Switch c. The bracket used for mounting the sensor magnet in the door depends on the depth of the door. If the door face is flat,

Página 25 - Screw Clamp

Appendix A. Door Switch 3. Assemble the sensor magnet with the bracket determined in step 1. Place the bracket in position so the edge of the senso

Página 26 - 6. Resistance to Weathering

Appendix A. Door Switch 7. Place the assembled sensor bracket over the two screws, making sure the sensor is aligned with the inside edge of the cas

Página 27 - 6.2 Primer and White Paint

Appendix A. Door Switch A.2 Example Programs A.2.1 CRBasic 'Program name: DOOR SWITCH CR1000.CR1 'Date written: 11/7/2005 ' '

Página 28

Appendix A. Door Switch A.2.2 Edlog ;{CR10X} ; File name = Door Switch CR10X.csi 7Nov2005 ; Door Switch Wiring ; +5V black - power to door swi

Página 29 - Appendix A. Door Switch

Appendix A. Door Switch 9: End (P95) 10: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 5 Interval (same units as above) 3:

Página 30 - Small Bracket

Appendix A. Door Switch A-8

Página 31 - Extended Door

Appendix B. 25458/28532 DIN-Rail Terminal Kits B.1 Introduction The 25458 (5-inch) or 28532 (9-inch) kit can facilitate wiring when many wires need

Página 32 - Lock Nut

Appendix B. 25458/28532 DIN-Rail Terminal Kits FIGURE B-2. 15920 Terminal Strip installation FIGURE B-3. 15907 End Plate installation B-2

Página 33 - A.2 Example Programs

Appendix B. 25458/28532 DIN-Rail Terminal Kits 2. Insert the 15909 Jumpers in the terminal strips as shown in FIGURE B-4. FIGURE B-4. 15909 Jumper

Página 34 - A.2.2 Edlog

Assistance Products may not be returned without prior authorization. The following contact information is for US and international customers residing

Página 35

Appendix B. 25458/28532 DIN-Rail Terminal Kits 4. Connect the wires to the terminals (see FIGURE B-6 and FIGURE B-7). The 8125 flat-bladed screwdri

Página 36

Appendix C. 28960 Stack Mounting Kit C.1 Introduction The 28960 Stack Mounting Kit is used to raise a component 3 in above the surface of the back

Página 37 - Terminal Kits

Appendix C. 28960 Stack Mounting Kit CR1000AM16/32BLegTop G ridLegEnclosureBackPlate FIGURE C-2. Assembled view of CR1000 and AM16/32B mounted on a

Página 38

Appendix C. 28960 Stack Mounting Kit Top GridLegScrew(8)Grommet(8)Leg FIGURE C-3. Contents of 28960 Stacking Kit FIGURE C-4. CR1000 mounted to Sta

Página 39

Appendix C. 28960 Stack Mounting Kit C-4 C.2 Mounting Procedure 1. Determine the spacing needed between the two legs. 2. Secure the legs to the ba

Página 40

Appendix D. Keeping Insects Out Of the Enclosure Campbell Scientific has published an application note regarding how to keep pests away from the equ

Página 41 - C.1 Introduction

Appendix D. Keeping Insects Out Of the Enclosure D-2

Página 43

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Página 44 - C.2 Mounting Procedure

Enclosures Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for li

Página 45

Enclosures Table of Contents ii C. 28960 Stack Mounting Kit...C-1 C.1 Introduction ...

Página 46

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 1. General Description Environmental enclosures protect ou

Página 47

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 1.1 Specifications Conduit Size (options “-SC”, “-DC”, “-

Página 48

ENC10/12, ENC10/12R, ENC12/14, ENC14/16, ENC16/18, PWENC12/14, PWENC14/16, and PWENC16/18 PWENC14/16 Internal Dimensions: 35.6 x 40.6 x 14 cm (14 x

Comentários a estes Manuais

Sem comentários