CSBUOY-DTRevision: 11/08Copyright © 2002-2008Campbell Scientific, Inc.

Página 2 - Warranty and Assistance

Section 1. Introduction 1-2 Solar Panel Typical Peak Power: 5 W Voltage @ Peak Power: 17.1 Vdc Current @ Peak Power: 300 mA Dimensions: 9.45” (2

Página 3 - CSBUOY-DT Shipping List

Section 2. CSBUOY-DT Description The CSBUOY-DT is designed to eliminate the use of hard-wire cable to connect the dissolved oxygen and water temperat

Página 4

Section 2. CSBUOY-DT Description 2-2 2.3 Communication Options • Direct RS-232 Connection to PC • RF401 Spread Spectrum Radio Connection to PC •

Página 5

Section 3. CSBUOY Installation 3.1 Site Selection The site should represent the general area being measured. Placement should allow the buoy to flo

Página 6

Section 3. CSBUOY Installation 3-2 Secure the mooring eye-bolts to a mooring line or the anchor eye-bolt to the anchor line to secure placement of bu

Página 7

Section 4. Communication The CSBUOY-DT can be used as a stand-alone monitoring system that communicates directly with the PC, or as a wireless sensor

Página 8

Section 4. Communication Programming Examples The following example allows the CR1000 to communicate with one CSBUOY-DT. ‘CR1000 Series Datalogger P

Página 9

Section 4. Communication 4: Sample (P70) 1: 13 Reps 2: 1 Loc [ Batt ] For further instruction on programming, please refer to th

Página 10 - Solar Panel

Section 4. Communication 4-4

Página 11 - 2.2 Standard Sensors

Section 5. Maintenance The CSBUOY-DT has been engineered to provide many years of reliable service. However, periodic maintenance is required to hel

Página 12 - 2.4 Power Supply

Warranty and Assistance The CSBUOY-DT is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use

Página 13 - 3.2 CSBUOY-DT Assembly

Section 5. Maintenance • Check inside of the instrument housing to ensure against water leakage. Any leakage will also be indicated by increase in

Página 14

Section 5. Maintenance 5.1.4.1 Air Calibration 1. Place the dissolved oxygen probe in the air, shaded from the sun. Wait for the measurement readi

Página 15 - Section 4. Communication

Section 5. Maintenance 5-4 This is a blank page.

Página 16

This is a blank page.

Página 17

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Página 18

CSBUOY-DT Shipping List Items packaged with the CSBUOY-DT for shipment include: • CSBUOY-DT • Solar panel with mounting brackets and cable • Lid •

Página 20 - 5.1.4 Calibration

Special Operating Notes 1. Check the shipping list in the front of the manual and make sure that all the parts checked off the list are with the CSBU

Página 22

CSBUOY-DT Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab

Página 24

Section 1. Introduction The CSBUOY-DT is programmed to communicate directly with a personal computer operating Device Configuration Utility software