Campbell-scientific BlackGlobe Temperature Sensor for Heat Stress Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
BlackGlobe Temperature Sensor for Heat Stress
FIGURE 6-4. BlackGlobe mounted to a crossarm (front view)
FIGURE 6-5. BlackGlobe mounted to a crossarm (back view)
7. Operation
7.1 Wiring
The wiring diagram for the BlackGlobe to a Campbell Scientific datalogger is
given in TABLE 7-1. Temperature is measured with one single-ended input
channel and a voltage excitation channel. Multiple probes can be connected to
the same excitation channel (the number of probes per excitation channel is
physically limited by the number lead wires that can be inserted into a single
voltage excitation terminal, approximately six).
7
Vista de página 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 31 32

Comentários a estes Manuais

Sem comentários