AVW200-series 2-Channel Vibrating Wire Spectrum Analyzer Modules
FIGURE 4-4. Example AM16/32-series to AVW200 Hookup
(multiplexers controlled by AVW200)
4.5.2 Datalogger Controlling the Multiplexer
When using SDI-12, the datalogger must control the multiplexer. Use the
CABLE4CBL-L cable to connect the AVW200 to the multiplexer if the
vibrating wire sensors contain a thermistor (see FIGURE 4-5). Use the
CABLE3CBL-L or equivalent cable if the vibrating wire sensors do not
contain a thermistor. The CLK and RESET lines on the multiplexer are used
instead of the CLK and RESET lines on the AVW200.