024A Met-One Wind Direction Sensor
'Main Program
BeginProg
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement Batt_Volt:
Battery(Batt_Volt)
'024A Wind Direction Sensor measurement WindDir:
BrHalf(WindDir,1,mV2500,1,1,1,2500,True,2000,250,1.0,0)
NewMult=360/WindDir
'Call Data Tables and Store Data
CallTable(Table1)
CallTable(Table2)
NextScan
EndProg
'CR3000
'Created by Short Cut (2.5)
'Declare Variables and Units
Public Batt_Volt
Public WindDir
Public NewMult
Units Batt_Volt=Volts
Units WindDir=degrees
'Define Data Tables
DataTable(Table1,True,-1)
DataInterval(0,60,Min,10)
Sample(1,WindDir,FP2)
EndTable
DataTable(Table2,True,-1)
DataInterval(0,1440,Min,10)
Minimum(1,Batt_Volt,FP2,False,False)
EndTable
'Main Program
BeginProg
Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement Batt_Volt:
Battery(Batt_Volt)
'024A Wind Direction Sensor measurement WindDir:
BrHalf(WindDir,1,mV5000,1,1,1,5000,True,2000,250,1.0,0)
NewMult=360/WindDir
'Call Data Tables and Store Data
CallTable(Table1)
CallTable(Table2)
NextScan
EndProg
12