Appendix B. Example Programs
B.1.2 CR10X Example Program
;{CR10X}
*Table 1 Program
01: 5.0000 Execution Interval (seconds)
1: Batt Voltage (P10)
1: 1 Loc [ Batt_Volt ]
2: Pulse (P3)
1: 1 Reps
2: 1 Pulse Channel 1
3: 22 Switch Closure, Output Hz
4: 2 Loc [ WS_ms ]
5: 0.8 Multiplier
6: 0.447 Offset
3: If (X<=>F) (P89)
1: 2 X Loc [ WS_ms ]
2: 4 <
3: 0.448 F
4: 30 Then Do
4: Z=F x 10^n (P30)
1: 0 F
2: 0 n, Exponent of 10
3: 2 Z Loc [ WS_ms ]
5: End (P95)
6: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
7: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
8: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
9: Average (P71)
1: 1 Reps
2: 2 Loc [ WS_ms ]
B-2
Comentários a estes Manuais