SDM-IO16 16 Channel Input/Output Expansion Module
11: If (X<=>F) (P89) ;check upper threshold
1: 1 -- X Loc [ Temp_1 ] ;to see if heater should
2: 3 >= ;be turned off
3: 25.5 F
4: 30 Then Do
12: Z=F (P30) ;if heater should be turned
1: 0 F ;off, enter a '0' into
2: 0 Exponent of 10 ;heater control location
3: 10 -- Z Loc [ Heat_1 ]
13: End (P95) ;end 'then do'
14: Else (P94) ;else, if the heater is off
15: Z=F (P30) ;enter a '0' into heater
1: 0 F ;control location
2: 0 Exponent of 10
3: 10 -- Z Loc [ Heat_1 ]
16: End (P95) ;end 'then do/else'
;End heater control logic
;Start cooler control logic
17: If (X<=>F) (P89) ;if 'cooler on' threshold
1: 1 -- X Loc [ Temp_1 ] ;is exceeded
2: 3 >=
3: 27.5 F
4: 30 Then Do ;then
18: Z=F (P30) ;put a '1' into cooler
1: 1 F ;control location
2: 0 Exponent of 10
3: 15 -- Z Loc [ Cool_1 ]
19: End (P95) ;end 'then do'
20: If (X<=>F) (P89) ;if cooler is on (cooler
1: 15 -- X Loc [ Cool_1 ] ;control location <>0)
2: 2 <>
3: 0 F
4: 30 Then Do ;then
21: If (X<=>F) (P89) ;check lower threshold to
1: 1 -- X Loc [ Temp_1 ] ;see if cooler should be
2: 4 < ;turned off
3: 24.5 F
4: 30 Then Do
22: Z=F (P30) ;if cooler should be turned off
1: 0 F ;put a '0' into cooler control
2: 0 Exponent of 10 ;location
3: 15 -- Z Loc [ Cool_1 ]
21